Gold Member Since 2013
Audited Supplier
Wuhan AQUCELL Membrane Technology Co., Ltd.

Water Filter, Water Treatment Engineeing, Ultrafiltration manufacturer / supplier in China, offering Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment, Aqu-250-F UF Membrane Water Treatment Equipment on Sale, Material Separation NF Membrane Element and so on.

(/ )

Supplier Homepage Product Water Purifier UF MEMBRANE NORMAL SERIES Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment

Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 500000 pcs/year
Payment Terms: T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: AQU-250
  • Usage: Water Treatment
  • Style: Tube
  • Certification: ISO
  • Transport Package: Carton or Wooden Crates
  • Origin: China
  • Type: Ultrafiltration /UF Membrane / Water Filter
  • Motive Force: Electric power
  • Performance: Efficient Filtration
  • Trademark: AQUCELL
  • Specification: UF Membrane Module/ Water Filter (10" - AQU-250)
  • HS Code: 8421212200
Product Description
Hollow Fiber UF Membrane AQU-250 water treatment equipment

Main features:
1. Wall thickness thickening of end cover and reinforced rib explosion-proof design make the pressure bearingg capacity over 1.6Mpa.
2. Central tube structure can make the water be distributed uniformly and the effects of back wash become better.
3. There are two outlets above and below that can back wash both by the two ones.
4. Especially design for quickly, conveniently fixing and good sealing property joint.
5. Stainless steel hoop make sure membrane not metamorphose and slack.
6. There are two kind of material of tube body to choose that can fill more demand of our clients.
7. End seal material: Epoxy resin with high hardness, excellent strength, superior toughness and good hygienism grade.


Technical Parameters:
Model No.Connection SizeMWCO
(Dalton)
Precision
(μm)
Flux
(L/·h)
Membrane Area
()
Operation pressure
(MPa)
Engineering
(T/H)
AQU-250ADN50100K0.0140~10032.7<0.210-150
AQU-250BDN50100K0.0140~10043.1<0.230-200
AQU-250CDN50100K0.0140~10054.3<0.2 Above 100

Feed Water Quality Requirement of Modified PVC UF Membrane Module
ParametersUnitsDesign ReferenceLimit
TSSmg/L<3050
TurbidityNTU<1015
Particle of Feed Waterµm<50100
Oil & Greasemg/L0<5
PH Range, Continuous Operation 6-92-12
PH Range, Short-Term Cleaning 2-122-12
Operating TemperatureºC25Lowest Temp. : 5ºC, Highest Temp : 45ºC
Operating PressureMPa0.06~0.20.3
TMP.MPa<0.10.2
Chlorine Tolerance, Continuous Operationmg/L50100
Chlorine Tolerance, Short-Term Cleaningmg/L100200

Instruction:
Make filtrate for 30mins→Top Backwash for 30s→Bottom Backwash for 30s→Forward Flush for30s ... Keep the cycle going.
For the specific process , please adjust as per case.


Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment
Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment
Hollow Fiber UF Membrane Aqu-250 Water Treatment Equipment
 
Send your message to this supplier
Avatar
Ms. Hao
*From:
To: Ms. Hao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now